2026-11-15 23:38:15 +00:00 | 0 commits to main since this release- Requests on one connection go one at a time: a lock per connection is
held for the write of a request's fragments and the wait for its reply,
and relayed requests take their gateway's lock. Concurrent callers could
interleave fragments (neither request then got a reply) and load the
mesh relay with several requests at once. - A device that stops answering fails fast: the one-at-a-time fallback of
the batched reads stops at the first request that gets no reply, instead
of waiting for a timeout per attribute. Relayed timeouts raise the new
RequestTimeout(aTimeoutError, still anIOError). - The fail-soft getters (
get_device_info(), the diagnostic getters,
get_vectra_info()and the other all-or-none reads, ...) read their
attributes in one batch instead of one request each, and an instance
reads the supported attributes once. - Dose schedule points with zero padding after the 9-byte primitive are
decoded; when an active point can't be decoded, the daily target and the
volume expected so far areNoneinstead of a too-low value
(decode_dose_schedule()). refill_container()raises the read error itself when the container size
can't be read, instead of reporting an unknown size.- The 1-byte Get/Set-attribute encoders raise
ValueErrorfor an index,
count or length above 255 instead of sending its low byte; insolation
tables are read in chunks that follow what came back and stop at index
255. - A relayed CoAP error reply without an inner frame is reported by its
response code, not logged as a malformed reply. start_scene()raisesValueErrorfor a scene id or duration that isn't
a 0-65535 integer, instead ofstruct.error.- A failed write no longer leaves its request pending,
connect()starts
with an empty receive buffer, and futures come from the running loop. get_device_summary()of a dosing pump that reports no container level
says so in its support note (and has"dose": None), instead of
claiming no parser is implemented.- Dosing pumps (
DoseV1, Versa):get_full_poll_batch()returns the
container level and dosing state asFullPollResult.dose(DoseInfo),
with the daily target and the volume expected so far from the dose
schedule. The schedule is cached by its checksum like the others; the
container size, monitor and sensor type are static attributes. get_dose_info(),set_container_volume()(also resets the remaining
volume, like the app) andrefill_container().mobius.dose: dose schedule points (DoseSchedulePoint, built on the
same point header as the light and pump points) with their 9-byte
DosePrimitiveValue, decoded and encoded; a dose schedule writer is not
implemented yet.- Attribute reference: the dosing pump attributes and their enums.
set_battery_backup_speed(),set_boosted_battery(),
set_schedule_intensity()andset_advanced_features()raise
ValueErrorfor aTrue/Falsenumeric value instead of writing it
as 1 or 0.support_tier()reports dosing pumps as"dose"instead of
"unsupported". Their schedule is read only: code that writes schedules
must not treat"dose"like a pump (the CLI's schedule-file load now
refuses anything but light and pump).get_device_summary()adds the
dosing pump'sDoseInfoas"dose"instead of the "no parser
implemented" note.