• v0.13.0 caa77f039d

    v0.13.0
    All checks were successful
    Release / test (HA latest) (push) Successful in 7m41s
    Release / test (HA 2026.8) (push) Successful in 7m45s
    Release / frontend (push) Successful in 1m26s
    Release / test (push) Successful in 0s
    Release / hacs (push) Successful in 1m28s
    Release / hassfest (push) Successful in 3m20s
    Release / validate (push) Successful in 0s
    Test / test (HA 2026.8) (push) Successful in 9m10s
    Test / test (HA latest) (push) Successful in 8m1s
    Test / frontend (push) Successful in 1m23s
    Release / release (push) Successful in 1m56s
    Validate / hacs (push) Successful in 1m28s
    Validate / hassfest (push) Successful in 3m9s
    Stable

    r3pek released this 2026-11-16 00:10:47 +00:00 | 0 commits to main since this release

    • Requires python-mobius 0.13.0.
    • Dosing pumps (Versa): container remaining, level and days left, dosed
      today, daily dose and expected dosed so far from the dose schedule,
      container size (sensor and number), container empty, a Refill container
      button, and the container monitoring and dosing halt state (enum
      sensors).
    • When a pump reports it doesn't monitor its container, the remaining,
      level, days left and container empty entities and the Refill button are
      unavailable.
    • Schedule services only write to lights and pumps (an allowlist instead
      of excluding pump (experimental) and unsupported), so dosing pumps,
      which python-mobius now reports as support tier dose, never get a pump
      schedule written.
    • A dosing pump that reports no container level says so in its support
      note, instead of "no parser implemented".
    • The container size number has the volume storage device class, and the
      dose entities' units use Home Assistant's constants.
    • A tank's devices are polled one at a time through the gateway instead
      of all at once.
    • Setup no longer waits for every device's first read: only the device
      that decides whether the entry is ready is read during setup, the others
      right after, with their entities created as soon as each is read. An
      unreachable device no longer holds up Home Assistant's startup.
    • The schedule card opens a schedule from the last poll when it is less
      than a minute old (checked against the device's checksum) instead of
      reading the whole schedule again; after a schedule write it reads from
      the device, and the written devices are refreshed.
    • Clock drift is only taken from polls that took under 10 seconds, and
      data kept through failed polls doesn't trigger clock syncs.
    • The gateway election and the periodic tank check run as tracked
      background tasks; a tank check doesn't start while the previous one is
      still running, and is cancelled when the entry is unloaded.
    • Fixed: after choosing "None" in the scene selection, the scene (and the
      cards' scene banner) stayed shown until the next poll: read right after
      the cancel, the devices still report the scene. It is now cleared at
      once on the devices the cancel reached, and every device is read again
      10 seconds after starting or cancelling a scene.
    • Fixed: a tank could get a new gateway through the tank check only once;
      after an elected gateway was lost a second time, the tank stayed without
      one until the entry was reloaded.
    • Fixed: the write_schedule_group and set_schedule_intensity services
      did nothing (the schedule card's Save and intensity changes reported
      success without writing): their handlers were never awaited.
    • Fixed: a failed poll left the device's Bluetooth connection open. The
      device then held an adapter slot and, still connected, didn't advertise,
      so reconnecting couldn't find it and a working gateway could be replaced
      as gone.
    Downloads