@ -2102,40 +2099,6 @@ This list was initially populated using information from the following sources:
| Siemens | VeSys | All Versions >=2019.1 SP1912 only if Teamcenter integration feature is used |Affected | No|[Siemens Advisory - SSA-661257: Apache Log4j Vulnerabilities](https://cert-portal.siemens.com/productcert/pdf/ssa-661247.pdf)| Currently no remediation is available. Find detailed mitigation steps [here](https://support.sw.siemens.com/en-US/knowledgebase/MG618363). See further recommendations from [Siemens Advisory SSA-661257](https://cert-portal.siemens.com/productcert/pdf/ssa-661247.pdf)| |12/18/2021 |
| Siemens | Xpedition Enterprise | All Versions >=VX.2.6 | Affected | No| [Siemens Advisory - SSA-661257: Apache Log4j Vulnerabilities](https://cert-portal.siemens.com/productcert/pdf/ssa-661247.pdf) |Currently no remediation is available. Find detailed mitigation steps [here](https://support.sw.siemens.com/en-US/knowledge-base/MG618343). See further recommendations from [Siemens Advisory SSA-661257](https://cert-portal.siemens.com/productcert/pdf/ssa-661247.pdf) | | 12/18/2021 |
| Siemens | Xpedition IC Packaging | All Versions >=VX.2.6 | Affected | No| [Siemens Advisory - SSA-661257: Apache Log4j Vulnerabilities](https://cert-portal.siemens.com/productcert/pdf/ssa-661247.pdf) |Currently no remediation is available. Find detailed mitigation steps [here](https://support.sw.siemens.com/en-US/knowledge-base/MG618343). See further recommendations from [Siemens Advisory SSA-661257](https://cert-portal.siemens.com/productcert/pdf/ssa-661247.pdf).| |12/18/2021 |
| Siemens Healthineers | ATELLICA DATA MANAGER v1.1.1 / v1.2.1 / v1.3.1 | | Affected | See Notes | [Siemens Healthineers](https://www.siemens-healthineers.com/en-us/support-documentation/cybersecurity/cve-2021-44228) | If you have determined that your Atellica Data Manager has a “Java communication engine” service, and you require an immediate mitigation, then please contact your Siemens Customer Care Center or your local Siemens technical support representative. | | 12/22/2021 |
| Siemens Healthineers | CENTRALINK v16.0.2 / v16.0.3 | | Affected | See Notes | [Siemens Healthineers](https://www.siemens-healthineers.com/en-us/support-documentation/cybersecurity/cve-2021-44228) | If you have determined that your CentraLink has a “Java communication engine” service, and you require a mitigation, then please contact your Siemens Customer Care Center or your local Siemens technical support representative. | | 12/22/2021 |
| Siemens Healthineers | DICOM Proxy VB10A | | Affected | See Notes | [Siemens Healthineers](https://www.siemens-healthineers.com/en-us/support-documentation/cybersecurity/cve-2021-44228) | Workaround: remove the vulnerable class from the .jar file | | 12/22/2021 |
| Siemens Healthineers | go.All, Som10 VA20 / VA30 / VA40 | | Affected | See Notes | [Siemens Healthineers](https://www.siemens-healthineers.com/en-us/support-documentation/cybersecurity/cve-2021-44228) | Workaround: In the meantime, we recommend preventing access to port 8090 from other devices by configuration of the hospital network. | | 12/22/2021 |
| Siemens Healthineers | go.Fit, Som10 VA30 | | Affected | See Notes | [Siemens Healthineers](https://www.siemens-healthineers.com/en-us/support-documentation/cybersecurity/cve-2021-44228) | Workaround: In the meantime, we recommend preventing access to port 8090 from other devices by configuration of the hospital network. | | 12/22/2021 |
| Siemens Healthineers | go.Now, Som10 VA10 / VA20 / VA30 / VA40 | | Affected | See Notes | [Siemens Healthineers](https://www.siemens-healthineers.com/en-us/support-documentation/cybersecurity/cve-2021-44228) | Workaround: In the meantime, we recommend preventing access to port 8090 from other devices by configuration of the hospital network. | | 12/22/2021 |
| Siemens Healthineers | go.Open Pro, Som10 VA30 / VA40 | | Affected | See Notes | [Siemens Healthineers](https://www.siemens-healthineers.com/en-us/support-documentation/cybersecurity/cve-2021-44228) | Workaround: In the meantime, we recommend preventing access to port 8090 from other devices by configuration of the hospital network. | | 12/22/2021 |
| Siemens Healthineers | go.Sim, Som10 VA30 / VA40 | | Affected | See Notes | [Siemens Healthineers](https://www.siemens-healthineers.com/en-us/support-documentation/cybersecurity/cve-2021-44228) | Workaround: In the meantime, we recommend preventing access to port 8090 from other devices by configuration of the hospital network. | | 12/22/2021 |
| Siemens Healthineers | go.Top, Som10 VA20 / VA20A_SP5 / VA30 / VA40 | | Affected | See Notes | [Siemens Healthineers](https://www.siemens-healthineers.com/en-us/support-documentation/cybersecurity/cve-2021-44228) | Workaround: In the meantime, we recommend preventing access to port 8090 from other devices by configuration of the hospital network. | | 12/22/2021 |
| Siemens Healthineers | go.Up, Som10 VA10 / VA20 / VA30 / VA40 | | Affected | See Notes | [Siemens Healthineers](https://www.siemens-healthineers.com/en-us/support-documentation/cybersecurity/cve-2021-44228) | Workaround: In the meantime, we recommend preventing access to port 8090 from other devices by configuration of the hospital network. | | 12/22/2021 |
| Siemens Healthineers | MAGNETOM AERA 1,5T, MAGNETOM PRISMA, MAGNETOM PRISMA FIT, MAGNETOM SKYRA 3T NUMARIS/X VA30A | | Affected | See Notes | [Siemens Healthineers](https://www.siemens-healthineers.com/en-us/support-documentation/cybersecurity/cve-2021-44228) | LOG4J is used in the context of the help system. Workaround: close port 8090 for standalone systems. Setup IP whitelisting for "need to access" systems to network port 8090 in case a second console is connected. | | 12/22/2021 |
| Siemens Healthineers | MAGNETOM Altea NUMARIS/X VA20A | | Affected | See Notes | [Siemens Healthineers](https://www.siemens-healthineers.com/en-us/support-documentation/cybersecurity/cve-2021-44228) | LOG4J is used in the context of the help system. Workaround: close port 8090 for standalone systems. Setup IP whitelisting for "need to access" systems to network port 8090 in case a second console is connected. | | 12/22/2021 |
| Siemens Healthineers | MAGNETOM ALTEA, MAGNETOM LUMINA, MAGNETOM SOLA, MAGNETOM VIDA NUMARIS/X VA31A | | Affected | See Notes | [Siemens Healthineers](https://www.siemens-healthineers.com/en-us/support-documentation/cybersecurity/cve-2021-44228) | LOG4J is used in the context of the help system. Workaround: close port 8090 for standalone systems. Setup IP whitelisting for "need to access" systems to network port 8090 in case a second console is connected. | | 12/22/2021 |
| Siemens Healthineers | MAGNETOM Amira NUMARIS/X VA12M | | Affected | See Notes | [Siemens Healthineers](https://www.siemens-healthineers.com/en-us/support-documentation/cybersecurity/cve-2021-44228) | LOG4J is used in the context of the help system. Workaround: close port 8090 for standalone systems. Setup IP whitelisting for "need to access" systems to network port 8090 in case a second console is connected. | | 12/22/2021 |
| Siemens Healthineers | MAGNETOM Free.Max NUMARIS/X VA40 | | Affected | See Notes | [Siemens Healthineers](https://www.siemens-healthineers.com/en-us/support-documentation/cybersecurity/cve-2021-44228) | LOG4J is used in the context of the help system. Workaround: close port 8090 for standalone systems. Setup IP whitelisting for "need to access" systems to network port 8090 in case a second console is connected. | | 12/22/2021 |
| Siemens Healthineers | MAGNETOM Lumina NUMARIS/X VA20A | | Affected | See Notes | [Siemens Healthineers](https://www.siemens-healthineers.com/en-us/support-documentation/cybersecurity/cve-2021-44228) | LOG4J is used in the context of the help system. Workaround: close port 8090 for standalone systems. Setup IP whitelisting for "need to access" systems to network port 8090 in case a second console is connected. | | 12/22/2021 |
| Siemens Healthineers | MAGNETOM Sempra NUMARIS/X VA12M | | Affected | See Notes | [Siemens Healthineers](https://www.siemens-healthineers.com/en-us/support-documentation/cybersecurity/cve-2021-44228) | LOG4J is used in the context of the help system. Workaround: close port 8090 for standalone systems. Setup IP whitelisting for "need to access" systems to network port 8090 in case a second console is connected. | | 12/22/2021 |
| Siemens Healthineers | MAGNETOM Sola fit NUMARIS/X VA20A | | Affected | See Notes | [Siemens Healthineers](https://www.siemens-healthineers.com/en-us/support-documentation/cybersecurity/cve-2021-44228) | LOG4J is used in the context of the help system. Workaround: close port 8090 for standalone systems. Setup IP whitelisting for "need to access" systems to network port 8090 in case a second console is connected. | | 12/22/2021 |
| Siemens Healthineers | MAGNETOM Sola NUMARIS/X VA20A | | Affected | See Notes | [Siemens Healthineers](https://www.siemens-healthineers.com/en-us/support-documentation/cybersecurity/cve-2021-44228) | LOG4J is used in the context of the help system. Workaround: close port 8090 for standalone systems. Setup IP whitelisting for "need to access" systems to network port 8090 in case a second console is connected. | | 12/22/2021 |
| Siemens Healthineers | MAGNETOM Vida fit NUMARIS/X VA20A | | Affected | See Notes | [Siemens Healthineers](https://www.siemens-healthineers.com/en-us/support-documentation/cybersecurity/cve-2021-44228) | LOG4J is used in the context of the help system. Workaround: close port 8090 for standalone systems. Setup IP whitelisting for "need to access" systems to network port 8090 in case a second console is connected. | | 12/22/2021 |
| Siemens Healthineers | MAGNETOM Vida NUMARIS/X VA10A* / VA20A | | Affected | See Notes | [Siemens Healthineers](https://www.siemens-healthineers.com/en-us/support-documentation/cybersecurity/cve-2021-44228) | LOG4J is used in the context of the help system. Workaround: close port 8090 for standalone systems. Setup IP whitelisting for "need to access" systems to network port 8090 in case a second console is connected. | | 12/22/2021 |
| Siemens Healthineers | Syngo Carbon Space VA10A / VA10A-CUT2 / VA20A | | Affected | See Notes | [Siemens Healthineers](https://www.siemens-healthineers.com/en-us/support-documentation/cybersecurity/cve-2021-44228) | Workaround: remove the vulnerable class from the .jar file | | 12/22/2021 |
| Siemens Healthineers | Syngo MobileViewer VA10A | | Affected | See Notes | [Siemens Healthineers](https://www.siemens-healthineers.com/en-us/support-documentation/cybersecurity/cve-2021-44228) | The vulnerability will be patch/mitigated in upcoming releases\patches. | | 12/22/2021 |
| Siemens Healthineers | syngo Plaza VB20A / VB20A_HF01 - HF07 / VB30A / VB30A_HF01 / VB30A_HF02 / VB30B / VB30C / VB30C_HF01 - HF06 / VB30C_HF91 | | Affected | See Notes | [Siemens Healthineers](https://www.siemens-healthineers.com/en-us/support-documentation/cybersecurity/cve-2021-44228) | Workaround: remove the vulnerable class from the .jar file | | 12/22/2021 |
| Siemens Healthineers | syngo Workflow MLR VB37A / VB37A_HF01 / VB37A_HF02 / VB37B / VB37B_HF01 - HF07 / VB37B_HF93 / VB37B_HF94 / VB37B_HF96 | | Affected | See Notes | [Siemens Healthineers](https://www.siemens-healthineers.com/en-us/support-documentation/cybersecurity/cve-2021-44228) | Please contact your Customer Service to get support on mitigating the vulnerability. | | 12/22/2021 |
| Siemens Healthineers | syngo.via WebViewer VA13B / VA20A / VA20B | | Affected | See Notes | [Siemens Healthineers](https://www.siemens-healthineers.com/en-us/support-documentation/cybersecurity/cve-2021-44228) | Workaround: remove the vulnerable class from the .jar file | | 12/22/2021 |
| Siemens Healthineers | X.Ceed Somaris 10 VA40* | | Affected | See Notes | [Siemens Healthineers](https://www.siemens-healthineers.com/en-us/support-documentation/cybersecurity/cve-2021-44228) | Workaround: In the meantime, we recommend preventing access to port 8090 from other devices by configuration of the hospital network. | | 12/22/2021 |
| Siemens Healthineers | X.Cite Somaris 10 VA30*/VA40* | | Affected | See Notes | [Siemens Healthineers](https://www.siemens-healthineers.com/en-us/support-documentation/cybersecurity/cve-2021-44228) | Workaround: In the meantime, we recommend preventing access to port 8090 from other devices by configuration of the hospital network. | | 12/22/2021 |
| Silver Peak | Orchestrator, Silver Peak GMS | | Affected | No | [Security Advisory Notice Apache](https://www.arubanetworks.com/website/techdocs/sdwan/docs/advisories/media/security_advisory_notice_apache_log4j2_cve_2021_44228.pdf) | Customer managed Orchestrator and legacy GMS products are affected by this vulnerability. This includes on-premise and customer managed instances running in public cloud services such as AWS, Azure, Google, or Oracle Cloud. See Corrective Action Required for details about how to mitigate this exploit. | | 12/14/2021 |